Created
March 11, 2019 11:28
-
-
Save ralfr/1cffab840efa1b56c07c624472ca6b9c to your computer and use it in GitHub Desktop.
Azure IoT Edge Deployment Manifest
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
{ | |
"$schema-template": "1.0.0", | |
"modulesContent": { | |
"$edgeAgent": { | |
"properties.desired": { | |
"schemaVersion": "1.0", | |
"runtime": { | |
"type": "docker", | |
"settings": { | |
"minDockerVersion": "v1.25", | |
"loggingOptions": "", | |
"registryCredentials": { | |
"ralfscontainers": { | |
"username": "$CONTAINER_REGISTRY_USERNAME_ralfscontainers", | |
"password": "$CONTAINER_REGISTRY_PASSWORD_ralfscontainers", | |
"address": "ralfscontainers.azurecr.io" | |
} | |
} | |
} | |
}, | |
"systemModules": { | |
"edgeAgent": { | |
"type": "docker", | |
"settings": { | |
"image": "mcr.microsoft.com/azureiotedge-agent:1.0", | |
"createOptions": {} | |
} | |
}, | |
"edgeHub": { | |
"type": "docker", | |
"status": "running", | |
"restartPolicy": "always", | |
"settings": { | |
"image": "mcr.microsoft.com/azureiotedge-hub:1.0", | |
"createOptions": { | |
"HostConfig": { | |
"PortBindings": { | |
"5671/tcp": [ | |
{ | |
"HostPort": "5671" | |
} | |
], | |
"8883/tcp": [ | |
{ | |
"HostPort": "8883" | |
} | |
], | |
"443/tcp": [ | |
{ | |
"HostPort": "443" | |
} | |
] | |
} | |
} | |
}, | |
"env": { | |
"OptimizeForPerformance": { | |
"value": "false" | |
} | |
} | |
} | |
} | |
}, | |
"modules": { | |
"tempSensor": { | |
"version": "1.0", | |
"type": "docker", | |
"status": "running", | |
"restartPolicy": "always", | |
"settings": { | |
"image": "mcr.microsoft.com/azureiotedge-simulated-temperature-sensor:1.0", | |
"createOptions": "{\"Env\":[\"MessageDelay=00:01:00\"]}" | |
} | |
}, | |
"CSharpFunction": { | |
"version": "1.0", | |
"type": "docker", | |
"status": "running", | |
"restartPolicy": "always", | |
"settings": { | |
"image": "${MODULES.CSharpFunction}", | |
"createOptions": {} | |
} | |
} | |
} | |
} | |
}, | |
"$edgeHub": { | |
"properties.desired": { | |
"schemaVersion": "1.0", | |
"routes": { | |
"CSharpFunctionToIoTHub": "FROM /messages/modules/CSharpFunction/outputs/* INTO $upstream", | |
"sensorToCSharpFunction": "FROM /messages/modules/tempSensor/outputs/temperatureOutput INTO BrokeredEndpoint(\"/modules/CSharpFunction/inputs/input1\")" | |
}, | |
"storeAndForwardConfiguration": { | |
"timeToLiveSecs": 7200 | |
} | |
} | |
} | |
} | |
} |