Created
February 3, 2023 17:40
-
-
Save grantstephens/e6604a4f20330c78443e59f69c12e3bb to your computer and use it in GitHub Desktop.
Monitoring of Grant Aerona ASHP using ESPHome and Serial Port to RS485 UART Converter
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
esphome: | |
name: ashp | |
esp32: | |
board: nodemcu-32s | |
wifi: !include wifi.yaml | |
api: | |
logger: | |
ota: | |
uart: | |
- rx_pin: GPIO23 | |
tx_pin: GPIO22 | |
baud_rate: 19200 | |
stop_bits: 2 | |
data_bits: 8 | |
id: hp_uart | |
parity: NONE | |
modbus: | |
- id: hp_modbus | |
uart_id: hp_uart | |
modbus_controller: | |
- id: hp_controller | |
address: 0x1 | |
modbus_id: hp_modbus | |
setup_priority: -10 | |
update_interval: 30s | |
sensor: | |
- platform: modbus_controller | |
name: "Heat Pump Return Water Temperature" | |
register_type: read | |
address: 0 | |
value_type: U_WORD | |
modbus_controller_id: hp_controller | |
unit_of_measurement: °C | |
filters: | |
multiply: 1.000000 | |
- platform: modbus_controller | |
name: "Heat Pump Compressor Operating Frequency" | |
register_type: read | |
address: 1 | |
value_type: U_WORD | |
modbus_controller_id: hp_controller | |
unit_of_measurement: Hz | |
filters: | |
multiply: 1.000000 | |
- platform: modbus_controller | |
name: "Heat Pump Discharge Temperature" | |
register_type: read | |
address: 2 | |
value_type: U_WORD | |
modbus_controller_id: hp_controller | |
unit_of_measurement: °C | |
filters: | |
multiply: 1.000000 | |
- platform: modbus_controller | |
name: "Heat Pump Current Consumption Value" | |
register_type: read | |
address: 3 | |
value_type: U_WORD | |
modbus_controller_id: hp_controller | |
unit_of_measurement: W | |
filters: | |
multiply: 100.000000 | |
- platform: modbus_controller | |
name: "Heat Pump Fan Control RPM" | |
register_type: read | |
address: 4 | |
value_type: U_WORD | |
modbus_controller_id: hp_controller | |
unit_of_measurement: rpm | |
filters: | |
multiply: 10.000000 | |
- platform: modbus_controller | |
name: "Heat Pump Defrost Temperature" | |
register_type: read | |
address: 5 | |
value_type: U_WORD | |
modbus_controller_id: hp_controller | |
unit_of_measurement: °C | |
filters: | |
multiply: 1.000000 | |
- platform: modbus_controller | |
name: "Heat Pump Outdoor Air Temperature" | |
register_type: read | |
address: 6 | |
value_type: U_WORD | |
modbus_controller_id: hp_controller | |
unit_of_measurement: °C | |
filters: | |
multiply: 1.000000 | |
- platform: modbus_controller | |
name: "Heat Pump Water Pump Control RPM" | |
register_type: read | |
address: 7 | |
value_type: U_WORD | |
modbus_controller_id: hp_controller | |
unit_of_measurement: rpm | |
filters: | |
multiply: 100.000000 | |
- platform: modbus_controller | |
name: "Heat Pump Suction Temperature" | |
register_type: read | |
address: 8 | |
value_type: U_WORD | |
modbus_controller_id: hp_controller | |
unit_of_measurement: °C | |
filters: | |
multiply: 1.000000 | |
- platform: modbus_controller | |
name: "Heat Pump Outgoing Water Temperature" | |
register_type: read | |
address: 9 | |
value_type: U_WORD | |
modbus_controller_id: hp_controller | |
unit_of_measurement: °C | |
filters: | |
multiply: 1.000000 | |
- platform: modbus_controller | |
name: "Heat Pump Plate Heat Exchanger Temperature" | |
register_type: read | |
address: 32 | |
value_type: U_WORD | |
modbus_controller_id: hp_controller | |
unit_of_measurement: °C | |
filters: | |
multiply: 1.000000 | |
- platform: modbus_controller | |
name: "Heat Pump Indoor Master Temperature Actual" | |
register_type: read | |
address: 33 | |
value_type: U_WORD | |
modbus_controller_id: hp_controller | |
unit_of_measurement: °C | |
filters: | |
multiply: 0.100000 | |
Sign up for free