s-tui help
usage: s-tui [-h] [-d] [--debug-file DEBUG_FILE] [-c] [--csv-file CSV_FILE]
[-t] [-j] [-nm] [-v] [-ct CUSTOM_TEMP] [-tt T_THRESH]
[-cf CUSTOM_FAN]
TUI interface:
The side bar houses the controls for the displayed graphs.
At the bottom of the side bar, more information is presented in text form.
* Use the arrow keys or 'hjkl' to navigate the side bar
* Toggle between stressed and regular operation using the radio buttons in 'Modes'.
* If you wish to alternate stress defaults, you can do it in 'Stress options'
* Select a different temperature sensors from the 'Temp Sensors' menu
* Change time between updates using the 'Refresh' field
* Use the <Reset> button to reset graphs and statistics
* Toggle displayed graphs by selecting the [X] check box
* If a sensor is not available on your system, N/A is presented
* If your system supports it, you can use the utf8 button to get a smoother graph
* Press 'q' or the <quit> button to quit
* Run `s-tui --help` to get this message and additional cli options
optional arguments:
-h, --help show this help message and exit
-d, --debug Output debug log to _s-tui.log
--debug-file DEBUG_FILE
Use a custom debug file. Default: _s-tui.log
-c, --csv Save stats to csv file
--csv-file CSV_FILE Use a custom CSV file. Default: s-tui_log_<TIME>.csv
-t, --terminal Display a single line of stats without tui
-j, --json Display a single line of stats in JSON format
-nm, --no-mouse Disable Mouse for TTY systems
-v, --version Display version
-ct CUSTOM_TEMP, --custom_temp CUSTOM_TEMP
Custom temperature sensors.
The format is: <sensors>,<number>
As it appears in 'sensors'
e.g
> sensors
it8792-isa-0a60,
temp1: +47.0C
temp2: +35.0C
temp3: +37.0C
use: -ct it8792,0 for temp 1
-tt T_THRESH, --t_thresh T_THRESH
High Temperature threshold. Default: 80
-cf CUSTOM_FAN, --custom_fan CUSTOM_FAN
Similar to custom temp
e.g
>sensors
thinkpad-isa-0000
Adapter: ISA adapter
fan1: 1975 RPM
use: -cf thinkpad,0 for fan1