* Asuro | |
* Unit: Drivers/ATA | |
* Description: ATA Driver | |
************************************************ | |
* Author: Aaron Hance | |
* Contributors: | |
************************************************ } | |
unit ATA; | |
interface | |
uses | |
util, | |
drivertypes, | |
console, | |
terminal; | |
type | |
intptr = ^uint32; | |
ATA_Device = record | |
end; | |
var | |
//0 = primary, 1 = secondary | |
dataPort : array[0..3] of uint16; | |
errorPort : array[0..3] of uint8; | |
sectorCountPort : array[0..3] of uint8; | |
lbaLowPort : array[0..3] of uint8; | |
lbaMidPort : array[0..3] of uint8; | |
lbaHiPort : array[0..3] of uint8; | |
devicePort : array[0..3] of uint8; | |
commandPort : array[0..3] of uint8; | |
controlPort : array[0..3] of uint8; | |
bytes_per_sector : uint16 = 512; | |
controller : TPCI_device; | |
procedure init(); | |
procedure identify(drive : uint8; bus : uint8); | |
procedure read28(sector : uint32); | |
procedure write28(sector : uint32; data : intptr; count : uint32); | |
procedure flush(); | |
implementation | |
procedure init(); | |
begin | |
//controller := device; | |
controller.address0 := $3F6; | |
controller.address1 := $376; | |
// 0x1f0, 0x170, 0x3F6, 0x376 | |
console.writehexln(controller.address0); | |
dataPort[0] := controller.address0; | |
errorPort[0] := controller.address0 + 1; | |
sectorCountPort[0] := controller.address0 + 2; | |
lbaLowPort[0] := controller.address0 + 3; | |
lbaMidPort[0] := controller.address0 + 4; | |
lbaHiPort[0] := controller.address0 + 5; | |
devicePort[0] := controller.address0 + 6; | |
commandPort[0] := controller.address0 + 7; | |
controlPort[0] := controller.address1 + 2; | |
console.writestringln('Checking for ATA devices:'); | |
identify($A0, $A0); | |
identify($B0, $A0); | |
end; | |
procedure identify(drive : uint8; bus : uint8); | |
var | |
status : uint8; | |
busNo : uint8; | |
i : uint16; | |
data : array[0..265] of uint16; | |
begin | |
outb(controlPort[0], 2); | |
busNo := 1; | |
if bus = $A0 then busNo := 0; | |
outb(devicePort[busNo], drive); | |
outb(controlPort[busNo], 0); | |
//psleep(1); | |
outb(devicePort[busNo], drive); | |
status := inb(commandPort[busNo]); | |
if status = $FF then begin | |
console.writestringln('No drives on bus'); | |
exit; | |
end; | |
outb(devicePort[busNo], drive); | |
//psleep(1); | |
outb(sectorCountPort[busNo], 0); | |
//psleep(1); | |
outb(lbaLowPort[busNo], 0); | |
//psleep(1); | |
outb(lbaMidPort[busNo], 0); | |
//psleep(1); | |
outb(lbaHiPort[busNo], 0); | |
//psleep(1); | |
outb(commandPort[busNo], $EC); | |
//psleep(1); | |
status := inb(commandPort[busNo]); | |
if status = $0 then begin | |
console.writestring('No drive found'); | |
exit; | |
end; | |
while (status and $80 = $80) and (status and $08 <> $08) do begin | |
status := inb(commandPort[busNo]); | |
console.writehexln(status); | |
end; | |
console.writehexln(status); | |
console.writestringln('Drive found!'); | |
end; | |
procedure read28(sector : uint32); begin | |
end; | |
procedure write28(sector : uint32; data : intptr; count : uint32); begin | |
end; | |
procedure flush(); begin | |
end; | |
end. |