working with a MIC 750 TL-X (which happens to generate a bit more 8)) with the below config. and yes, | |
this works fine along with the sensors of the platform growatt_solar. | |
```yaml | |
uart: | |
tx_pin: GPIO4 | |
rx_pin: GPIO5 | |
baud_rate: 9600 | |
modbus: | |
modbus_controller: | |
- id: modbus_gw750 | |
sensor: | |
- platform: modbus_controller | |
modbus_controller_id: modbus_gw750 | |
# | |
# sensor returning the currently set limit read from the register for showing it in HA | |
# | |
name: "Limit %" | |
id: gw750_limit_set | |
register_type: holding | |
address: 3 | |
unit_of_measurement: "%" | |
value_type: U_WORD | |
number: | |
- platform: modbus_controller | |
modbus_controller_id: modbus_gw750 | |
# | |
# creating a number entity and it's corresponding slider in HA | |
# and writes it to the register on change | |
# | |
name: GW750 Limit | |
id: gw750_limit | |
address: 3 | |
register_type: holding | |
value_type: U_WORD | |
min_value: 10 | |
max_value: 100 | |
step: 1 | |
``` |