For controlling the temperature, Desired_Temperature isn't touched directly. | |
Desired_Temperature_Command is used to change the temperature and | |
Desired_Temperature will react on this changes. | |
*/ | |
var Number WINDOW_OPEN_TEMPERATURE = 8.0 | |
val org.eclipse.xtext.xbase.lib.Functions$Function1<float, void> update_temperature = [ temperature | | |
if (Contact_Window.state == OFF) { | |
// Set actual Temperature and desired Temperature | |
Desired_Temperature_Command.postUpdate(temperature) | |
Last_Desired_Temperature.postUpdate(temperature) | |
} else { | |
// Only set desired Temperature | |
// Will be activated untill window is closed | |
Last_Desired_Temperature.postUpdate(temperature) | |
} | |
] | |
// Change the vents temperature on command changes only if the window is closed | |
rule Command_Desired_Temperature | |
when | |
Item Desired_Temperature_Command received update | |
then | |
Desired_Temperature.sendCommand(Desired_Temperature_Command.state) | |
end | |
// Reduce the temperature if the window is opened | |
// And save the current temperature to restore it later | |
rule Close_Vent_If_Window_is_opened | |
when | |
Item Contact_Window received update ON | |
then | |
logInfo("Window","window opened") | |
Desired_Temperature_Command.postUpdate(WINDOW_OPEN_TEMPERATURE) | |
end | |
// Set the last desired temperature if the window is closed | |
rule Open_Vent_If_Window_is_closed | |
when | |
Item Contact_Window received update OFF | |
then | |
logInfo("Window","window closed") | |
Desired_Temperature_Command.postUpdate(Last_Desired_Temperature.state) | |
end | |
// Check, if Desired_Temperature_Command equals Desired_Temperature | |
rule Check_Temperature_For_Consistency | |
when | |
Time cron "0 /5 * * * ?" | |
then | |
if (Desired_Temperature_Command.state != Desired_Temperature.state) { | |
if (Contact_Window.state == OFF) { | |
logInfo("Warning","Desired Temperature differes from Command Temperature") | |
Desired_Temperature.sendCommand(Desired_Temperature_Command.state) | |
} | |
} | |
end |