RPI-PiFace Controlling an AC units Remote Control This is part of a tutorial. http://penbang.sysbase.org/other_projects/Tutorials/controlling_a_remote_control_with_the_piface_digital.pdf
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
#!/usr/bin/env python3 | |
import pifacedigitalio as pf | |
import time | |
import subprocess | |
import urllib | |
from xml.dom import minidom | |
def get_temp(cc): | |
##Thanks to http://stackoverflow.com/questions/16070885/python-yahoo-weather-xml-parse-works-with-2-7-1-but-not-2-6-1 | |
CITY_ID = cc | |
TEMP_TYPE = 'c' | |
WEATHER_URL = 'http://xml.weather.yahoo.com/forecastrss?w=' + CITY_ID +' &u=' + TEMP_TYPE | |
WEATHER_NS = 'http://xml.weather.yahoo.com/ns/rss/1.0' | |
dom = minidom.parse(urllib.urlopen(WEATHER_URL)) | |
ycondition = dom.getElementsByTagNameNS(WEATHER_NS, 'condition')[0] | |
CURRENT_OUTDOOR_TEMP = ycondition.getAttribute('temp') | |
return CURRENT_OUTDOOR_TEMP | |
def switch_control(): | |
'''You can think of this a virtual toggle switch. | |
The value for ON and OFF is 1(one) | |
I am not sure why, but I am assuming it is due to the method of wiring(IC pin) | |
The initial state is imperative for the operation. e.g. If the remote is on, the switch will close it. | |
''' | |
pfd = pf.PiFaceDigital() | |
pfd.relays[1].value = 0 | |
time.sleep(0.7) #I read somewhere that it is not recommended to switch the relay immediately | |
pfd.relays[1].value = 1 | |
def run(): | |
cc = '721943' #Example Rome http://weather.yahoo.com/italy/lazio/rome-721943/ | |
start = '18' | |
stop = '17' | |
state = remember() | |
print('The Current State is '+state) | |
print('Based on Yahoo! Outdoor Temp = %s C\n' %get_temp(cc)) | |
if get_temp(cc) >= start: | |
print('Temp is at start range [%s]' %start) | |
if 'on' in state: | |
print('AC is on') #Not the actual AC, rather the remote | |
pass | |
elif 'off' in state: | |
print('Starting...') | |
switch_control() | |
b = open('state', 'w+') | |
b.write('on') | |
b.close() | |
if get_temp(cc) <= stop: | |
print('Temp is at stop range [%s]' %stop) | |
if 'off' in state: | |
print('AC is off') | |
pass | |
elif 'on' in state: | |
print('Stopping') | |
switch_control() | |
b = open('state', 'w+') | |
b.write('off') | |
b.close() | |
else: | |
pass | |
def remember(): | |
'''You need to enter the first state manually | |
1- on | |
2- off | |
''' | |
a = open('state', 'r') | |
state = a.read() | |
a.close() | |
return state | |
run() |